

The upward vector has been used for all kinds of lifting procedures, but perpendicular vector of adhesion is more important for proper lifting. The pressure on the cogs gets dispersed to the mesh that surrounds the entire central thread. Cogs act as an assistant, so that the tissue adhesion through the mesh happens quickly after the procedure.


.png)


.png)
360º 3D Mesh Scaffold Design
The pressure on the cogs gets dispersed to the mesh that surrounds the entire central thread. Cogs act as an assistant, so that the tissue adhesion through the mesh happens quickly after the procedure.
Prevent Briding Effect and Scar Plate Formation
The tissues that recognize the mesh pore linings as a foreign substance will encircle them via adhesion. Pore sizes of at least 1 mm must be maintained to prevent a bridging effect- which induces a scar plate formation.
Deployment Method - Zig Zag Technigue
Because the cog direction changes towards the opposite direction, the mesh scaffolds can strongly and effectively prevent the recurrence of tissue sagging. Multiple Insertions and Re-insertion in Zig-Zag Directions Significantly Increases the Fixation Strength and Overall Tensile Strength of the Mesh Surures.
Tensile strength and Adhesion
The pressure on the cogs gets dispersed to the mesh that surrounds the entire central thread. Cogs act as an assistant, so that the tissue adhesion through the mesh happens quickly after the procedure.
Strand Equilibrium of Tension
Mesh-Penetrating Strands are responsible for the overall tensile strength of the suture via dispersion of forces. These forces apply to the strand and does not influence the mesh in any measure.
Minimized Patient's Discomfort
Triple Parallel Positioning of the 3D meshes at the fixation area significantly increases the fixation strength. The suspension force against the gravitational pull is equally distributed into 3 segments, leading to reduction in patient's discomfort.

OMEDELBAR LYFTEFFEKT
Omedelbart lyft vid applicering men som även ger ett succesivt naturligt lyft av vävnaden under kommande 6 månader.
SÄKER OCH UNIK TEKNOLOGI
Tack vare Tesslifts unika teknologi och specialdesignade nät så avlastas hullingarna. Med den konventionella tråden centreras lyftet till själva hullingen. Med Tesslift minskar därför risken till att vävnaden slits sönder och orsakar asymmetri och obehag.
LÅNG HÅLLBARHET
Tesslift ger ett långt och hållbart resultat! Resultatet håller upp
till 4 gånger längre än den konventionella tråden.
MINIMALT INVASIV PROCEDUR
Lokalbedövning och omedelbart synbart resultat. Tidsåtgång för behandlingen är ca 30 minuter.
KORT ÅTERHÄMTNINGSTID
Mesh fullbordar 98 procent av vävnadsinväxten inom 2 veckor.
Introduction video of TESS
CERTIFIERA DIG I TESSLIFT